Atonarp’s AMS-1000 is the industry’s first ever quantitative real time miniaturized molecular sensor. Now, you can monitor not only the most minuscule traces of gases, but also the precise quantity of each for optimized process control as well as detect the presence of harmful contaminants. With a rugged Faraday Cup and calibration against the Capacitance Diaphragm Gauge (CDG), the AMS-1000 operates in high pressure environments without the need for external pumps. Its customizable proprietary software puts precision molecular analysis for Lyophilization, industrial process control and select semiconductor applications at your fingertips.
Compact and sleek, the AMS 1000 can be easily retrofitted onto any process control tool. It’s fitted with our proprietary miniaturized array of micro-quadrupoles along with integrated small turbo and roughing pumps.
The AMS 1000 delivers highly accurate measurements due to its innovative electronics and signal processing capability. It performs quantitative molecular scans in less than 10mS, allowing for real-time process control optimization. With its cloud-connected software, you can leverage the data analytics for unparalleled process insight.
The AMS 1000 operates at ~3 orders of magnitude higher pressure thanks to the miniature design of Atonarp’s array of micro-quadrupole rods.
Ideal for fast repeatable measurements needed in process control applications, the AMS 1000 spans 6+ decades of concentration dynamic range, down to ppm levels. It is calibrated within the same pressure range against the gold standard Capacitance Diaphragm Gauge (CDG).
With a smart modular design, the AMS 1000 guarantees the industry’s lowest downtime, with easy on-site replacement of consumable parts and in-built usage diagnostics. Few required consumables and low maintenance translates into a low total cost-of-ownership, and hassle-free operation.
256 x 204 x 196 mm
WEIGHT9 Kgs
Miniaturized quadrupole arrays contain smaller rods, and more quadrupoles, than a conventional quadrupole detector.
The standard-sized array is unable to operate at high pressure and requires external pumps which are space-consuming.
AMS 1000 | Traditional MS | |
---|---|---|
Quantitative | |
Qualitative / Semi-quant |
Directly calibrated against a Gold Standard | |
Indirectly by extrapolation, hence inaccurate and requires frequent calibration |
Can diferentiate between isobaric masses: CO2 (m/z = 44 ) vs. Propane (m/z = 44) | Yes, via its fragmentation ions fingerprinting algorithm | |
Chamber sampling pressure | Up to 2 Torr | |
Peak resolving capability | |
|
Quantitative accuracy (%) | |
|
Maintenance free | |
|
Roughing pump | |
|
Automated calibration / tuning | |
|